1-) INTRODUCTION OF THE SYSTEM:
We call our residence systems as “STEELIFE RESIDENCE SYSTEMS” designed with overall coarse and thin materials and whose light galvanized sheet profiles and main conveyor systems are produced.
In accordance with data of projects whose static estimations and architectural designs are accomplished on the basis of region and projects, below materials are used;
According to (DIN EN 10326) standard;
(S320GD+Z, +AZ) (Erdemir quality no: 1332)
Yielding point : 3200 kg/cm2 (320 N/mm2)
Tensile strength : 3900 kg/ cm2 (390 N/mm2)
(S350GD+Z, +AZ) (Erdemir quality no: 1335)
Yielding point : 3500 kg/cm2 (350 N/mm2)
Tensile strength : 4200 kg/ cm2 (420 N/mm2)
2-) PRODUCTION TECHNOLOGY OF CONVEYOR SYSTEM:
Production is done via full automated roll forming machines. Profiles of the construction create required forms through continue profile lines and necessary installation and connection spaces are opened via computer control. Any welding process shouldn't be implemented during production and assembly process. Combinations are accomplished by special bolt and/or screws. Seismic and static calculations required for the location of the construction are performed by Sap2000, CFS, STA4CAD, BRICSCAD, HAYESCAD programmes in accordance with load value defined by relevant project and standards.
3-) STEELIFE HOME COMPATIBILITY STANDARDS
3-A) STEEL AND CONSTRUCTION:
TS 11372: Light Weight Steel Structures-Composed of Cold Formed Steel Members-Desing Rules . Taken From :AISI 1968, CTÐCM 1978, Cissel, J.H and W.E. Quinsey, Drability of Lightweight Steel Construction, Part 1, University of Michigon Engineering Research Bulletin, No:30 June 1942
TS 648: Building Code for Steel Structures . Taken From: DIN 1030, DIN 4114, SIA 161
TS 6793 : Loads Due To Use and Occupancy In Residential and Public Buildings . Taken From : ISO 2103 (1986)
TS 498: Design Loads for Buildings . Taken From : BSI Codr of Basic Data for the Desing of Building Chapter VRevizyon 17.11.1987)- WÐND FORCES in ENGÐNEERÐNG DIN 1055 (Peter Sachs, Pergamon Preds - 1972) DIN 18196 TS 4047, Beton Kalender 1977
TS ENV 1993-1-2: Eurocode 3 - Design of steel structures - Part 1-2: General rules - Structural fire design . Taken From : EN 1993-1-2 : 2005 , EN 1993-1-2-EQV; BS EN 1993-1-2-EQV;
TS 4561 : Rules for Plastic Design of Steel Structures .Taken From : L.S.Beedle, "Plastic Design of Steel Frames", John Wiley and Son., Inc., New York, 1958, P.G.Hofge, "Plastic Analysis of Syructures", Mc Graw-Hill Book Co., Newyork 1959,
TS ENV 1090-1: Execution of steel structures - Part 1 : General rules and rules for buildings . Taken From : ENV 1090-1 -EQV; DIN V ENV 1090-1-EQV; BS DD ENV 1090-1-EQV; OENORM ENV 1090-1-EQV;
TS ENV 1090-3: Execution of steel structures - Part 3: Supplementary rules for high yield strength steels Taken From :. ENV 1090-3 (1997-02-00)-EQV; DIN V ENV 1090-3 (2003-03)--; BS DD ENV 1090-3 (2000-12-15)--; OENORM ENV 1090-3 (1998-07-01)--;
TS ENV1998-3: Eurocode 8: Design of structures for earthquake resistance - Part 3: Assessment and retrofitting of buildings .Taken From : EN 1998-3:2005
TS EN 10326: Continuously hot-dip coated strip and sheet of structural steels - Technical delivery conditions. Taken From : EN 10326-EQV; BS EN 10326 -EQV; NF A36-326, NF EN 10326 -EQV; DIN EN 10326-EQV;
TS EN 10327: Continuously hot-dip coated strip and sheet of low carbon steels for cold forming - Technical delivery conditions Taken From : EN 10327-EQV; DIN EN 10327 -EQV; NF A36-327, NF EN 10327 -EQV; BS EN 10327-EQV;
TS EN 10162: Cold rolled steel sections - Technical delivery conditions - Dimensional and cross-sectional tolerances Taken From : , EN 10162 -EQV; DIN EN 10162 -EQV; BS EN 10162 -EQV; NF A37-101 -EQV
3-B) INSULATION (HEAT-ENERGY,ACOUSTIC,SOUND,WATER):
TS 825: Thermal Insulation in Building . Taken From : prEN 832*ISO 10456*ISO9164*DIN 4108-1* DIN 4108-2* DIN 4108-3* DIN 4108-4* DIN 4108-5* Commission of the European Communuties(Thermal Insulation and Ventilationin BuildingsA Comparison of Requirements EEC-Member States Situation),CEN TC 89,CEN TC 89 N 422 E,CEN TC 89 N 425 E
TS 901-1 EN 13162: Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification Taken From: EN 13162-EQV; DIN EN 13162 -EQV; BS EN 13162 --; NF P75-403 --;
TS EN 12086: Thermal insulating products for building applications-Determination of long term water absorption by immersion Taken From : EN 12086:1997--; BS EN 12086--; NF P75-215--; DIN EN 12086--; EN 12086:1997-EQV;
DIN 4109: Acoustic sound value for houses.
TS 2381-2 EN ISO 717-1: Acoustics - Rating of sound insulation in buildings and of building elements - Part 1::Sound insulation diffused with air. Taken From : EN ISO 717-1:1996/A1:2006
TS 2381-2 EN ISO 717-2: Acoustics - Rating of sound insulation in buildings and of building elements - Part 2: Impact sound insulation Taken From : EN ISO 717-2:1996/A1:2006
TS EN 29052-1: Acoustics-Determination of Dynamic Stiffness-Part 1-Materials Used Under Floating Floors in Dwellings Taken From :. ISO 9052-1 (1989)--; EN 29052-1, EQV , 89/106/ EEC--; BS EN 29052-1--; NF EN 29052-1--; DIN EN 29052-1--; EN 29052-1:1992--;
TS 7316 EN 13163: Thermal insulation products for buildings- Factory made products of expanded polystrene (EPS)- Specification Taken From : EN 13163--; BS EN 13163--; DIN EN 13163--;
TS EN 13500: Thermal insulation products for buildings - External thermal insulation composite systems (ETICS) based on mineral wool - Specification Taken From : EN 13500-EQV; DIN EN 13500-EQV; BS EN 13500--; NF P75-426--; SN EN 13500-EQV; OENORM EN 13500--;
3-C) FIRE RESISTANCE STANDARTS:
DIN 4102: Building materials's and building parts fire action.
TS 1263 : Fire-Resistance Classes and Fire Resistance Test Methods for the Elements of Building Construction Taken From: ISO 834-1975, DIN 4102/2-1977, DIN 4102/4-1981
DIN 1365-1: Fire Resistance Test: Load Bearing Parts: Chapter 1: Walls
DIN 1365-2: Fire Resistance Test: Load Bearing Parts : Chapter 2: Floors and Roofs
TS EN 13501-1: Thermal insulation products for buildings - External thermal insulation composite systems (ETICS) based on mineral wool - Specification Taken from : EN 13500-EQV; DIN EN 13500-EQV; BS EN 13500--; NF P75-426--; SN EN 13500-EQV; OENORM EN 13500--;
3-D) CONNECTION AND INSTALLATION MATERIAL STANDARTS :
TS EN 20898-7: Mechanical properties of fasteners-Part 7: Torsional test and minimum torques for bolts and screws with nominal diameters 1 mm to 10 mm Taken From: ISO 20898-7:1999 EQV--; EN 20898-7:1995 --; BS EN 20898-7:1995 EQV--; NF E25-100-7 NF EN 20898-7:1995 EQV--; DIN EN ISO 20898-7:1995 EQV--; EN 20898-7:1995--;
TS 3611EN 20898-2: Mechanical properties of fasteners-Part 2:Nuts with specified proof load values-Coarse thread Taken From : ISO 898-2:92, EQV--; EN 20898-2:93, EQV , 87/404/EEC--; BS EN 20898-2:94, EQV--; DIN EN 20898-2:94, EQV--; EN 20898-2:93--;
3-E) EXTERNAL WALL & INTERNAL WALL STANDARTS:
TS EN 520: Gypsum plasterboards - Definitions, requirements and test methods Taken From : EN 520-EQV; DIN EN 520-EQV; BS EN 520-EQV; NF P72-600-EQV;
TS 1475 : Rules for Erection of Gypsum Partition Wall Components and Boards Taken From : Directives Communes/Pour L'Agrement des Cloisons en Platre-Union Europeenne pour L'Agrement Technique Claus La Construction DIN 18180, DIN 18182
TS EN 12369-1: Wood-based panels - Characteristic values for structural design - Part 1: OSB, particleboards and fibreboards Taken From : EN 12369-1-EQV; DIN EN 12369-1-EQV; BS EN 12369-1-EQV; NF B51-078-1-EQV;
TS EN 300: Oriented strand boards (OSB) - Definitions, classification and specifications Taken From : EN 300 -EQV; DIN EN 300 --; BS EN 300 --; NF B54-115--;
3-F) ELECTRICAL INSTALLATION STANDARTS:
16.June 2004 dated and 25494 refered Electrical Installation Code.
21 August 2001 dated and 24500 refered Grounding Code.
3-G) GENERAL CODES:
R.G.26.07.2002 / 24822: Fire protection code.
ABYYHY 2007: Building code for earthquake resistance
|